相关链接
联系方式
  • 通信地址:前进大街2699号
  • 邮编:130012
  • 电话:0431-85168292
  • 传真:0431-85168292
  • Email:cwang@jlu.edu.cn
当前位置:> 首页 > 论文著作 > 正文
Fabrication of Pt/polypyrrole hybrid hollow microspheres and their application in electrochemical biosensing towards hydrogen peroxide
作者:Xiujie Bian, Xiaofeng Lu ? , E. Jin, Lirong Kong,Wanjin Zhang, CeWang
关键字:Pt nanoparticles; PPy; Electrocatalytic; Hydrogen peroxide reduction
论文来源:期刊
具体来源:TALANTA
发表时间:2010年
Pt/polypyrrole (PPy) hybrid hollow microspheres were successfully prepared by wet chemical method via Fe3O4 template and evaluated as electrocatalysts for the reduction of hydrogen peroxide. The as-synthesized products were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectra (XPS), X-ray diffraction (XRD), inductive coupled plasma emission spectrum (ICP) and Fourier-transform infrared spectra (FTIR) measurements. The results exhibited that ultra-high-density Pt nanoparticles (NPs) were well deposited on the PPy shell with the mean diameters of around 4.1 nm. Cyclic voltammetry (CV) results demonstrated that Pt/PPy hybrid hollow microspheres, as enzyme-less catalysts, exhibited good electrocatalytic activity towards the reduction of hydrogen peroxide in 0.1 M phosphate buffer solution (pH = 7.0). The composite had a fast response of less than 2 s with linear range of 1.0–8.0 mM and a relatively low detection limit of 1.2 μM (S/N = 3). The sensitivity of the sensor for H2O2 was 80.4 mA M?1 cm?2.